¶ÔÈýÖÖPEȼÆø¹ÜµÀ³£ÓõÄʾ×ÙÏß¾ÙÐÐÆÊÎö

ȪԴ£º/ Ðû²¼Ê±¼ä£ºÈÕÆÚ£º2022-07-19 0´Î
ÏÖÔÚ £¬Êг¡ÉÏÓжàÖÖʾ×ÙÏß¡£ÄÄÖÖʾ×ÙÏ߽Ϻà £¬¸üÓÐÀûÓÚ¶ÔÂñµØ×ÔÈ»Æø¹ÜµÀµÄºã¾Ã¸ú×Ù¶¨Î»ÖÎÀí¡£ÐèÒª²âÊÔʾ×ÙÏßµÄÐÔÄÜÒÔÑ¡Ôñ¸üºÏÊʵÄʾ×Ù¼Á¡£½ðÊôË¿¡£
At present, there are many kinds of trace lines on the market. Which kind of tracing line is better, which is more conducive to the long-term tracking and positioning management of buried natural gas pipelines. It is necessary to test the performance of the tracer line to select a more suitable tracer. Wire.
Í­°ü¸ÖÊÇÓɸÖоÏߺÍÀÎÀΰü¹üÔÚÆäÖÜΧµÄÍ­²ã×é³ÉµÄ½ðÊôо¡£Íâ²àΪPE·À¸¯²ã¡£Í­Æð´«µ¼Î¢ÈõµçÐźŵÄ×÷Óà £¬¸ÖË¿ÆðÖ§³Ö×÷Óá£
Copper clad steel is a metal core composed of steel core wire and copper layer tightly wrapped around it. The outer side is PE anticorrosive coating. Copper plays the role of conducting weak electrical signals, and steel wire plays the role of support.
ͭоÏßÒ»Ñùƽ³£ÓÉÄÚ²ãͭоÏß¡¢ÖÐÐIJã¾øÔµ»¤Ì׺ÍÍâ²ã±£»¤Ì××é³É¡£Í­°üÂÁÓÉÂÁоÏߺͽ«ÆäÀÎÀΰü¹üÐγɽðÊôоµÄÍ­²ã×é³É £¬Íâ²ãΪPE·À¸¯²ã¡£
Copper core wire is generally composed of inner copper core wire, intermediate insulating sheath and outer protective sheath. Copper clad aluminum is composed of aluminum core wire and copper layer tightly wrapped to form metal core, and the outer layer is PE anticorrosive coating.
ÓÉÓÚ¸ÖÖÆȼÆø¹ÜµÀÍâ²ã·À¸¯²ãΪËÜÁϲã»ò¾ßÓоøÔµ·À¸¯ÐÔÄܵÄÍ¿²ã £¬Æä½á¹¹ÀàËÆÓÚÍ­°ü¸Ö¡¢Í­Ð¾Ïß¡¢Í­°üÂÁºÍÆäËûÍâ²ã £¬ËüÃÇÒ²ÊǾßÓоøÔµºÍ·À¸¯ÐÔÄܵÄËÜÁϲã¡£Òò´Ë £¬ÎÒÃǽÓÄÉÁ½¸öµÈЧÎï £¬½ÓÄÉPCM¹ÜµÀµçÁ÷Ë¥¼õÂÊ·¨À´²âÊÔʾ×ÙÏß·À¸¯²ãµÄƽ¾ù¾øÔµÖÊÁ¿¡£
As the outer anti-corrosion layer of steel gas pipeline is plastic layer or coating with insulation and anti-corrosion performance, its structure is similar to copper-clad steel, copper core wire, copper-clad aluminum and other outer layers, which are also plastic layers with insulation and anti-corrosion performance. Therefore, we use two equivalents and PCM pipeline current decay rate method to test the average insulation quality of the anti-corrosion coating of the tracer line.
ȼÆøʾ×ÙÏß³§¼ÒÒÔΪ¼ì²âÔ­ÀíÊÇÏòʾ×Ù¼ÁÊ©¼ÓÒ»¶¨ÆµÂʵĵçÁ÷ÐźÅ £¬µçÁ÷´Óʾ×Ù¼Á´«µ½Ô¶´¦»áÖð½¥Ë¥¼õ¡£ÆäË¥¼õÓëʾ×Ù¼ÁËÜÁϲãµÄ¾øÔµµç×èÂÊÓйØ¡£Ê¾×Ù¼ÁËÜÁϲãµÄƽ¾ù¾øÔµµç×èÂÊÔ½¸ß £¬µçÁ÷Ë¥¼õÔ½Âý £¬·´Ö®ÒàÈ»¡£
The manufacturer of gas tracing line believes that the detection principle is to apply a certain frequency of current signal to the tracer, and the current will gradually decay when it is transmitted from the tracer to a distance. Its attenuation is related to the insulation resistivity of the tracer plastic layer. The higher the average insulation resistivity of the tracer plastic layer, the slower the current attenuation, and vice versa.
ȼÆøʾ×ÙÏß
Í­°ü¸Ö¡¢Í­Ð¾Ïß¡¢Í­°üÂÁÈý¸ùʾ×ÙÏßÂñÉèÔÚͳһÌõPEȼÆø¹ÜµÀÉÏ·½¡£PE¹ÜµÀ×ܳ¤Ô¼717m £¬È»ºó²âÊÔÁËÈý¸ùʾ×ÙÏߵĵ¼µçÐԺͷÀ¸¯ÐÔ¡£ºÍÇ¿¶È £¬È»ºó¾ÙÐÐÊý¾ÝÆÊÎö £¬ÒÔ¶Ôʾ×Ù¼Á¾ÙÐÐÆÀ¹À¡£
Copper clad steel, copper core wire and copper clad aluminum are buried above the same PE gas pipeline. The total length of PE pipe is about 717m, and then the conductivity and corrosion resistance of three tracer wires are tested. And intensity, and then conduct data analysis to comprehensively evaluate the tracer.
Í­°ü¸Öʾ×ÙÏßÔÚÇ¿¶È·½ÃæÓÅÊÆÏÔ×Å¡£ÔÚ´«µ¼Ì½²âÐźÅʱҲÄÜÖª×ã̽²âºÍʾ×ÙµÄÐèÒª £¬Ê©¹¤Ò²Ô½·¢Àû±ã¡£ÈôÊÇÄÜ×öºÃÌÖÂ۵ķÀ¸¯´¦Àí £¬Ê¾×ÙÏßÊÇ»®ËãµÄ¡£
Copper clad steel tracer wire has obvious advantages in strength. It can also meet the needs of detection and tracing when conducting detection signals, and the construction is more convenient. If the anti-corrosion treatment of the joint can be done well, the tracer line is cost-effective.
ͭоÏßʾ×ÙÏ߶Լì²âÐźŵĴ«µ¼ÐÔÓÅÁ¼ £¬µ«ÌÖÂÛ²¿Î»µÄ·À¸¯ÒªÁì½ÏÁ¿¼òÆÓ £¬ÌÖÂÛ²¿Î»µÄ·À¸¯ÖÊÁ¿²»¿É°ü¹Ü £¬Ç¿¶ÈÉԲÒò´Ë £¬Í­Ð¾Ïß²»ÒËÓÃ×÷µØÂñȼÆø¹ÜµÀµÄʾ×ÙÏß¡£
The copper core trace line has excellent conductivity to the detection signal, but the anti-corrosion method of the joint is relatively simple, the anti-corrosion quality of the joint can not be guaranteed, and the strength is slightly poor. Therefore, copper core wire should not be used as a tracer wire for buried gas pipelines.
Í­°üÂÁʾ×ÙÏßÔÚÇ¿¶ÈºÍÐźŴ«µ¼·½ÃæûÓÐÓÅÊÆ¡£ÈôÊÇÌÖÂÛ·À¸¯´¦ÀíÇ·ºÃ £¬1-2aÄھͻáÍêÈ«ÇÖÊ´¶ÏÁÑ¡£Òò´Ë £¬²»ÊÊÓÃÓÚÂñµØȼÆø¹ÜµÀµÄʾ×Ù¼Á¡£
Copper clad aluminum tracer wire has no advantage in strength and signal transmission. If the anti-corrosion treatment of the joint is not good, it will be completely corroded and broken within 1-2a. Therefore, it is not suitable for tracer of buried gas pipeline.
Òò´Ë £¬ÎÒÃǶÔÒÔÉÏÈýÖÖ³£ÓõÄʾ×ÙÏß¾ÙÐÐÁ˲âÊÔ £¬´Óʾ×ÙÏߵ絼ÂÊ¡¢Ê¾×ÙÏßÌÖÂÛ·À¸¯´¦Àí¡¢Ê¾×ÙÏßÇ¿¶ÈµÈ·½ÃæΪPEÊäÆø¹ÜµÀʾ×ÙÏßµÄÑ¡ÔñÌṩÁ˲ο¼¡£ÎªÄúÌṩ×ÊÖú £¬Çë¹Ø×¢ÎÒÃÇÏàʶ¸ü¶à£¡
Therefore, we have tested the above three commonly used tracer lines, which provides a reference for the selection of PE gas transmission pipeline from the aspects of tracer line conductivity, anti-corrosion treatment of tracer line joints, and tracer line strength. To help you, please follow us Learn more!